PWR-C1-715WAC-P
715W AC 80+ platinum Config 1 Power Supply
Specifications:
Power Supply Rated Maximum Output Power:
- 715W
Total Output BTU:
- 2440 BTU/hr (715W)
Input-Voltage Range and Frequency:
- 100 to 240 VAC, 50 to 60 Hz
Input Current:
- 10-5A
Output Ratings:
- -56V at 12.8A
Output Holdup Time:
- 20 ms minimum at 100VAC
Power-Supply Input Receptacles:
- IEC 320-C16 (IEC60320-C16)
Power Supply Efficiency:
- Platinum Efficiency
MTBF (Mean Time Between Failures):
- 1,054,881 hours (ranges from 1.05M to 2.6M depending on temperature, input voltage, and vendor)
Power Cord Rating:
- 15A
Physical Specifications:
Dimensions (H x W x D):
- 1.58 x 3.25 x 12.20 inches
Weight:
- 2.6 lb (1.2 kg)
Operating Temperature:
Normal operating temperature and altitudes:
- -5°C to +45°C, up to 5000 feet (1500m)
- -5°C to +40°C, up to 10,000 feet (3000m)
- Minimum ambient temperature for cold start is 32°F (0°C)
Short-term exceptional conditions:
- -5°C to +50°C, up to 5000 feet (1500m)
- -5°C to +45°C, up to 10,000 feet (3000m)
- -5°C to +45°C, at sea level with single fan failure
- Not more than the following in one-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences
Storage Temperature:
- -40° to 158°F (-40° to 70°C)
Relative Humidity Operating and Nonoperating Noncondensing:
- 5% to 90% noncondensing
Altitude:
- 10,000 ft. (3000 meters), up to 45°C
EMI and EMC Compliance:
- FCC Part 15 (CFR 47) Class A
- ICES-003 Class A
- EN 55032 Class A
- CISPR 32 Class A
- AS/NZS 3548 Class A
- BSMI Class A (AC input models only)
- VCCI Class A
- EN 55024, EN300386, EN 61000-3-2, EN 61000-3-3
- EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6




