AP8858
Rack PDU 2G, Metered, ZeroU,16A, 100-240V, (18) C13 & (2) C19
– Ideal for colocation, large or remote data center operators
– Plan capacity & balance loads with +/- 3% metering accuracy (amps, volts, kW, kWh)
– Enables improved energy efficiency and scope 1 and 3 emissions tracking
– Easily monitor and manage through EcoStruxure IT and other platforms
– Stay on top of potential circuit overloads with user-defined alarms
———
Overview
———
AP8858 Presentation: APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Specifications
—–
Main
—–
Name: AP8858
Colour: Black
Product or component type: PDU
PDU type: Metered
Provided equipment: Installation guide, Rack mounting brackets, Serial configuration cable, Safety guide
————–
Complementary
————–
Input Voltage: 200 V, 208 V, 230 V
Height: 90.2 cm
Width: 5.6 cm
Output Voltage: 100 V, 200 V, 208 V, 230 V
Depth: 4.4 cm
Net weight: 2.93 kg
mounting location: Side
Mounting preference: No preference
Input Plug Type: IEC 60320 C20
mounting mode: Rack-mounted
Rack units: 0U
mounting position: Vertical
[In] rated current: 16 A
Permissible voltage: 100…240 V
Input current limits: 20 A
Load capacity: 3300 VA
Network frequency: 50/60 Hz
Outlet type and quantity: 18 IEC 60320 C13, 2 IEC 60320 C19
————
Environment
————
product certifications: METI Denan, VDE
Standards: CSA C22.2 No 60950, IEC 60950, UL 60950-1
Relative humidity: 5…95 %
Operating altitude: 0…10000 ft
Ambient air temperature for storage: -25…65 °C
Storage Relative Humidity: 5…95 %
Storage altitude: 0.0000000000…15240.0000000000 m
————–
Packing Units
————–
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 112.4 cm
Package 1 Width: 16.2 cm
Package 1 Length: 10.7 cm
Package 1 Weight: 4.191 kg
———————
Contractual warranty
———————
Warranty: 2 years repair or replace